This product does not contain dehp.
Power injectable port needle.
Designed for patient comfort.
So yes you can access a powerport with a huber needle but no if there is a chance that the patient will have a ct scan.
Lower insertion and penetration force than non siliconized port access needles.
Powerloc max power injectable infusion set without y injection site 19 gauge x 1 5 in.
Bard winged infusion set.
Port access needles power injectable.
They are mri conditional at 3 tesla.
Smart port ct injectable port.
A power port needle is specifially made to withstand the pressure used to inject the ct dye.
Identifying a smart port power injectable port.
300 psi 22 gauge needle with 2 ml s maximum infusion rate.
Safestep huber needle set.
300 psi 19 gauge and 20 gauge needles with 5 ml s maximum infusion rate.
Smart port power injectable ports can be identified by the smart angle identifier technology on the ct and ct low profile power injectable port models.
Huberplus safety infusion set.
Note the ct is visible on x ray image of the newer models of ports as an identifier that this port is power injectable.
0142015 powerloc max power injectable infusion set without y injection site 20 gauge x 1 5 in.
Miniloc safety infusion set.
Needles provide the flexibility of use including power injection of contrast media.
The smart port ct family of power injectable ports which include low profile and mini models.
Angiodynamics vortex revolutionizes port design with a rounded chamber that has no sludge harboring corners or dead spaces.
As the needle is removed from the port and enters the base of the needle an orange safety shield rotates over the needle point and the needle locks into place.
If the dye were to be injected into a huber needle that needle would break inside the port.
Implantable infusion ports can be identified subcutaneously by feeling the top of the septum and the.
Powerloc ez safety infusion set.
Ez huber safety infusion set.
The power injectable implantable infusion port device consists of two primary components.
Needle allows for higher pressure and flow rates for power injections with port a cath power p a c.
0142215 powerloc max power injectable infusion set without y injection site 22 gauge x 1 5 in.
It is indicated for power injection of contrast media up to 5 ml sec.
The ct engraving on all models can be seen through chest x ray or scout scan.
Power injection is performed using a power injectable needle only.
The gripper plus power p a c.
Miniloc sis power injection capability powerloc sis.
Gripper plus power p a c.
A tactile feel an audible click and visual confirmation verifies the lockout for safe removal.
Vascular access vortex ports.
And 300 psi pressure limit setting when used with a gripper plus huber needle.
Powerloc safety infusion set.